A coated copper clad steel tracer wire of 12 gauge or larger kub item 300362 shall be installed with all buried plastic mains and services.
Tracer wire for water line installation.
Hold the tracer wire at the start of the pipe near the street and fasten it to the pipe by wrapping it with electrical tape.
The insulation is a high molecular weight and high density polyethylene which is resistant to abrasions crushing chemicals oils and moisture.
Benefits of tracer wire vs.
The tracer wire shall be laid within 6 inches of the plastic pipe where practical and directly above if possible.
5 steps to installing a tracer wire system step 1 conduct.
Ansi gptc install tracer wire as a single continuous wire.
An example would be install 12 solid copper wire with jacket.
So when you are designing a piping system either for water or sewage you need to make sure to use tracer wire.
The electrical wire tracer is laid alongside the pipes or lines during installation in order to find them at a later date for safe digging.
Installation install tracer wire along the pipe above or to the side of the pipe.
Recommended 2 6 separation.
Contact with the pipe is allowed but shall be minimized.
Trace wire systems must be installed as a single continuous wire except where using approved connectors.
Proper installation and location to the pipe termination of the wire and connecting the wire properly when splicing or connecting to a service are very important as well.
Splicing of wire if necessary shall be done in such a way to.
Tracer wire should not be wrapped around pipe or connectors except at the riser.
Step 2 connect.
These two wires are not interchangeable.
Underground tracer wire is available in sizes 14 through 6 awg in an array of colors depending on the intended use.
When you install copperhead tracer wire and complete locating system you can expect value reliability and the best service industry wide.
The installation of a tracer wire helps solve many problems for builders and construction workers.
Trace wire installation shall be performed in such a manner that allows proper access for connection of line tracing equipment proper locating of wire without loss or deterioration of low frequency 512hz signal for distances in excess of 1 000 linear feet and without distortion of signal caused by multiple wires being installed in close proximity to one another.
Many municipalities are writing tracer wire specifications that are too broad.
Choosing copper clad steel tracer wire has.
The first step is selecting your tracer wire.
Step 2 roll out the tracer wire along the pipe taping it to the pipe every 5 feet.
Open cut copperhead industries exclusive high strength copper clad steel tracer wire combines the strength and flexibility of fully annealed high carbon steel with the conductivity and corrosion resistance of solid copper.