If you are unable to diagnosis and fix the problem with your heat pump or if you have additional questions contact your local trane comfort specialist.
Trane fan motor not running.
If no fan turning and no humming n.
It happened about 3 months ago as well but i took the top off turned it upside down and was able.
Reset your thermostat then adjust the temperature to a comfortable level.
Sometimes excessive dust can build up and cause the motor to burn out.
Before replacing the board make sure you check more commonly defective parts particularly the fan motor capacitor and the fan motor itself.
The relay board provides voltage to many components of the air conditioner including the fan motor.
This is usually because an old filter has not been replaced.
Outside fan doesn t run.
The blower motor is not functioning.
This is probably the most common cause.
Trane condenser fan motor does not run.
Just cool air blows out the vents.
Most fans are energized by a fan relay.
To find just the right part enter your model number.
Your local trane comfort specialist can help.
Your heat pump may also have old or worn out wiring that needs to be repaired or tightened by a trane comfort specialist.
No cold air comes out the vents.
Sometimes it will stop after about 2 minutes but starting yesterday it will not stop the noise.
If the unit is still running continuously contact a trane comfort specialist.
If the relay board isn t working properly the fan might not run.
This is much easier and less expensive to repair than a motor going bad.
Common solutions 3 related videos 9 common solutions for.
Trane xe 1000 fan motor problem solved the fan on the outside trane xe1000 unit is making a terrible squealing noise when running otherwise everything working fine cools heats house like always.
Why is the fan on my heat pump not running.
Try replacing the fuse or flipping the circuit breaker to the closed position.
It could be a bad fuse or you might have flipped a breaker.
Relay boards are often misdiagnosed.
Heat pumps that require additional service.
If you experience a blower motor failure you will need professional assistance in replacing it.
If your air conditioner seems to be running constantly your thermostat could be set too high.
A weak faulty or shorted capacitor can prevent the motor from running.
Trane condenser fan motor does not run.
Contact an air conditioner troubleshooting pro.
They usually stick open never sending the signal to the motor.
If your unit s fan is not working efficiently or at all however your unit s overall performance can diminish.
We can help you find your model number right away.